Fixed Hydrogen Detectors

Hydrogen Gas Detectors >> Fixed Hydrogen Detectors

The range of Fixed/ Ceiling Mounted Hydrogen Gas Detectors incorporate our Patented Technology for selective, specific and intelligent sensing of Hydrogen with zero interference from other gases.

Since our Patented Sensors do not consume any power for operation, they are intrinsically safe and do not require a bulky flame-proof enclosure. With an in-situ calibration feature, using our Gas Calibration Kit, our Patented Sensors offer very high accuracy and stability over their entire range of measurement.

These sensors do not get damaged even upon exposure to 100% pure hydrogen and can endure several high alarm situations without the need for replacement. An industry leading range of 0% to 5% H2 v/v in Air has made our range of Patented Sensors highly desirable for durable, hassle-free and sturdy Hydrogen gas sensing.

Our sensors are capable of providing the following kinds of outputs:

  • 0V to 5V control signal analog output FIXaHY-5%-025V, CHS-HTR-PH-100-5V-CM & CHS-HTR-PH-100-5V-B

  • 4mA to 20mA control signal analog output FIXaHY-5%-4220mA-FLP

  • Voltage free changeover contacts FIXaHY-5%-COC-IS & FIXaHY-5%-COC-FLP

  • RS 232 MODBUS Protocol FIXaHY-5%-AI & FIXaHY-8CH-AI

  • RS 485 MODBUS Protocol FIXaHY-5%-AI & FIXaHY-8CH-AI

  • Local Display and Voltage free changeover contact FIXaHY-8CH

In order to make our Patented Technology accessible to all, we have adopted an inclusive approach to marketing.

We collaborate with all kinds of solution providers who need hydrogen sensors for integrating into their solutions.

Overview of Fixed & Ceiling Mounted Hydrogen Detectors

Note:
* Subject to limited time exposure, as described elaborately in the User Manual supplied along with the Detector
# FSD = Full Scale Display
@ We provide IP 68 Cast Aluminium Enclosure. Special request for ABS enclosure can be served for 50+ quantity

Highest range of 0% to 5% H2 v/v in Air (equivalent to 0% to 125% LEL). FIXaHY-5%-025V has 0V to 5V analogue control signal output.

Know more >>

Highest measurement range of 0% to 5% H2 v/v in Air (equivalent to 0% to 125%LEL)

FIXaHY-5%-4220mA-FLP has 4mA to 20mA analogue control signal output.

Know more >>

Highest measurement range of 0% to 5% H2 v/v in Air (equivalent to 0% to 125% LEL)

FIXaHY-5%-AI has Digital output in RS 232 or RS 485 MODBUS Protocol

Know more >>

Highest measurement range of 0% to 5% H2 v/v in Air (equivalent to 0% to 125% LEL)

FIXaHY-5%-COC-IS has Digital output as 2 sets of voltage-free changeover contacts with NO and NC states.

Know more >>

Highest measurement range of 0% to 5% H2 v/v in Air (equivalent to 0% to 125% LEL)

FIXaHY-5%-COC-FLP has Digital output as 2 sets of voltage-free changeover contacts with NO and NC states

Know more >>

Highest measurement range of 0% to 5% H2 v/v in Air (equivalent to 0% to 125%LEL)

CHS-HTR-PH-100-5V-CM is compatible with FIXaHY-8CH or FIXaHY-8CH-AI or third-party systems

Know more >>

Highest measurement range of 0% to 5% H2 v/v in Air (equivalent to 0% to 125% LEL)

CHS-HTR-PH-100-5V-B is Compatible with FIXaHY-8CH or FIXaHY-8CH-AI or third-party systems

Know more >>

Looking for any product/solutions to meet your needs.
Feel free to contact us